Description: The life of the MP roller expires soon or has expired.
Remedy: 1) Turn the machine off. 2) Release the LEVER-MP LONG(JC66-03501A) from the TRAY-MP MAIN(JC63-03673A). 3) Release the LEVER-MP FRONT and LEVER-MP REAR from the TRAY-MP MAIN. 4) Remove the right cover after releasing the locking pins. 5) Remove 1 screw securing GUIDE-PUSHER DEVE F. 6) Remove 8 screws securing RACKET-R/F COVER RIGHT. 7) Remove 8 screws. Disassemble the DUPLEX from the COVER-RIGHT. 8) Unplug the connector. 9) Turn the MP Assy and remove 2 screws. 10)Remove 4 screws from the MP LOWER GUIDE and MP UPPER GUIDE. 11) Remove the E-Ring. Release the MP-PICK UP(JC90-01167A) from the HOLDER-MP ROLLER(JC61-05282A) 12)Remove the SHAFT-LOCK (JC66-00939A). Remove the COUPLER-TORQUE-LIMITER 500 from the MP-PICK UP. 13)Release and replace the MP-PICKUP RUBBER(JC90-01168A) 14)Assemble the MP unit. 15)Enter SVC mode. To enter SVC mode, press 1,2,3 number keys simultaneously. When the password dialog box appears, enter “1934” and press the “OK” button. 16)Select “Roller” (INFORMATION > Supply Status > Field Replacement Unit > Roller) 17)Select “P/up roller MP”. The “RESET” button will be activated. Click “RESET” to clear the MP pick up roller. 18)Exit SVC mode by pushing the home button.