Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi H2-5048 — Samsung CLX8650ND

Code: H2-5048

Display: Finisher door is open. Close it
Description: Finisher Door is Opened. Power(24V) supply is cut off, and then stop the operation of Finisher.
Remedy: Check if the all door of finisher closed. If the error still occurs, check the followings. 1) Is the all Doors of Finisher closed? a) Close the doors(JC63-03941A) opened. 2) Is the Front Door (JC63-03941A) Switch (SW1) working? a) Check if the Switch(SW1) and the Actuator(JC63-03941A) is abnormality. b) Check if the connector(JR10 8360) of Switch is disconnected. c) Check if the connector(JR10 8360) J2 on the main control board(JC81-07242A) is disconnected. d) Check for continuity in the wire harness and whether the harness is damaged(JR10 8360), replace it if required. e) Replace the Door switch(SW1). f) Replace the Finisher main control board(JC81-07242A).