Display: Finisher Failure #H2-506x. Turn off then on, after checking finisher Finisher Failure #H2-507x. Turn off then on, after checking finisher Finisher Failure #H2-5A50. Check finisher
Description: Communication error between the IOT and the Finisher.
Remedy: If the error still occurs, check the followings. 1) Check if the Finisher of the interface cable(JC81-03470A) should be connected with the IOT. a) Power Switch of the IOT Off. b) IOT and Finisher of the interface cable(JC81-03470A) is connected. c) Power Switch of the IOT On. 2) Is the LEDs of the Main Control Board (JC81-07242A) working? < Open the Bottom cover(SJ10 6160) of Finisher > a) The Finisher of the Doors(JC63-03941A, JC81-07249B) should remain closed to all. b) Red, yellow color LED is ON, and Green LED flickers. c) Replace the Finisher main control board(JC81-07242A). 3) Check the Interface Cable(JC81-03470A) of Main Control Board(JC81-07242A). a) Check if the connector(JC81-07242A) J1,J3 on the main control board (JC81-07242A) is disconnected. b) Check for continuity in the wire harness and whether the harness is damaged(JC81-03470A), replace it if required. c) Replace the Finisher main control board(JC81-07242A). 4) Replace the Finisher main control board(JC81-07242A)