Display: Motor Failure: #A1-5312. Turn off then on. Call for service if the problem persists Motor Failure: #A1-5313. Turn off then on. Call for service if the problem persists
Description: Magenta toner is not supplied normally.
Remedy: • A1-5312 : Toner supply is stopped during operation. • A1-5313 : Toner is not supplied. 1) Open the front cover. If the magenta toner pipe is blocked, open it. 2) Turn the machine off then on. If the error persists, check the following steps. 3) Enter SVC mode. Select the magenta toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 111-0020 : Toner Dispense Motor Magenta 4) If the motor is not operational, measure the magenta motor power with DVM. a) If 24V power is generated, replace the magenta toner supply motor(JC93-00446A). b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02429A).