Display: LSU Failure #U2-6142: Turn off then on. LSU Failure #U2-6143: Turn off then on.
Description: Hsync signal of the LSU is abnormal.
Remedy: 1) Turn the machine off then on. Check for the LSU motor operation sound during warm-up. 2) Print a demo page to check that the machine operates normally. 3) If the problem persists, check the following : a) Turn the machine off and open the side cover. Unplug and reconnect the LSU cable. Print a demo page to check that the machine operates normally. b) Turn the machine off and open the side cover. Unplug and reconnect the LSU cable on main board. Print a demo page to check that the machine operates normally. c) If the LSU cable(JC39-01688A) is defective, replace it. Check that the LSU motor makes a sound after turning the machine on. d) If the problem persists, replace the LSU(JC97-04010A).