Mã lỗi A3-3310, A3-3311, A3-3312, A3-3410, A3-3411, A3-3412 — Samsung CLX9201ND

Code: A3-3310, A3-3311, A3-3312, A3-3410, A3-3411, A3-3412

Display: Sensor Failure: #. Turn off then on. Call for service if the problem persists
Description: Outer temperature/humidity sensor is defective.
Remedy: • A3.3310 / A3.3311 / A3.3312 : Temperature function is abnormal. • A3.3410 / A3.3411 / A3.3412 : Humidity function is abnormal. 1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine Test Routines > 109-0013 Outer Temperature ) 2) Remove the left cover. (Refer to 3.3.4 Temperature Sensor) Measure the resistance value of the connector at both ends. If the value is not in 47.5KOhm - 52.5KOhm(at 25C), replace the sensor(JC93-00486A) 3) If the harness and sensor are normal, replace the main board (JC92-02429A).