Display: Fuser Unit Failure: #U1-2113. Fuser Unit Failure: #U1-2119.
Description: The thermistor can’t measure temperature. The hear-roller will not heat-up.
Remedy: 1) Turn the machine off. Re-install the fuser unit, then turn the machine on. 2) Remove the fuser unit. After openinging the jam cover, check if jammed or wrapped paper is in the fuser unit. 3) If the problem persists, check the following : a) Check if the Halogen lamp (110V : 4713-001630 / 220V : 4713-001631) is broken or disconnected. b) Check if the AC connection of the Halogen lamp is disconnected or contaminated. c) Check if the thermostat(4712-001098) is disconnected. d) Check if the non-contact type thermistor(1404-001453)is broken. 4) If the problem persists, replace the Fuser unit(110V : JC91-01064A, 220V : JC91-01063A). 5) If the problem persists, replace the Main board(JC92-02429A) or FDB board(110V : JC44-00210A, 220V : JC44-00211A), SMPS(110V : JC44-00093A, 220V : JC44-00100A)