Display: Fuser Unit Failure: #U1-2316. Fuser Unit Failure: #U1-2317
Description: Temperature of the fuser changes abnormally.
Remedy: 1) Turn the machine off. Re-install the fuser unit, then turn the machine on. 2) Check if the power voltage is normal. (Is the voltage during the operation+-10% of the rated voltage?) 3) If the problem persists, Check the following : a) Check if the Halogen lamp (110V : 4713-001630 / 220V : 4713-001631) is broken or disconnected. b) Check if the AC connection of the Halogen lamp is disconnected or contaminated. c) Check if the thermistat(4712-001098) is disconnected. d) Check if non-contact type thermistor(1404-001453) is broken. 4) If the problem persists, replace the Fuser unit(110V : JC91-01064A, 220V : JC91-01063A). 5) If the problem persists, replace the Main board(JC92-02429A) or FDB board(110V : JC44-00210A, 220V : JC44-00211A), SMPS(110V : JC44-00093A, 220V : JC44-00100A)