Mã lỗi A3-3111, A3-3112, A3-3113, A3-3114 — Samsung CLX9251NA

Code: A3-3111, A3-3112, A3-3113, A3-3114

Display: Sensor Failure: #. Turn off then on. Call for service if the problem persists
Description: The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to a defective harness.
Remedy: • A3-3111 : Center NC sensor is in short status. • A3-3112 : Center NC sensor is in open status. • A3-3113 : Side NC sensor is in short status. • A3-3114 : Side NC sensor is in open status. 1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 109-0000 : Fuser Temperature A • 109-0010 : Fuser Temperature B 2) Remove and disassemble the fuser unit. 3) Measure the resistance value of the thermistor (1404-001453). If the measured value is out of 307KOhm - 430KOhm at 25C, replace the thermistor. 4) Install the fuser unit after replacing the thermistor. 5) If the error persists, replace the fuser unit (JC91-01063A(220V) / JC91-01064A (110V)). 6) If the error persists after replacing fuser unit, replace the main board(JC92-02429A).