Display: Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists. Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists.
Description: Regi/MP motor operation is abnormal.
Remedy: • A1-1111 : Regi/MP motor is stopped but machine recognizes it as operational. • A1-1113 : Regi/MP motor is operating but machine recognizes status as "Stopped". 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit. 3) Remove the rear cover after removing 10 screws. 4) Check if the Regi/MP motor connector is connected correctly. 5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0000) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)). - If the control signal is abnormal, replace the main board(JC92-02429A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.