Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi A1-4310 — Samsung CLX9251ND

Code: A1-4310

Display: Motor Failure: #A1-4310. Turn off then on. Call for service if the problem persists
Description: The contact of ITB Unit is abnormal. / The resistance value of the first transfer roller is abnormal.
Remedy: 1) Enter SVC mode. Select the T1 engage motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0080) Push the start button and check the motor operation. 2) If the motor is not operational, a) Open the side cover. Check if the ITB connector is connected correctly or is deformed. b) If the harness is defective, replace it. c) Remove the ITB unit from the machine. Check if the photo interrupter sensor is contaminated or assembled properly. d) If the photo sensor is defective, replace it. e) If the motor is operational but the engage gear is not operational, replace the main drive unit(JC93-00723A). 3) If there is a motor noise or the motor is not operational normally, check the following : a) Remove the rear cover. Check if the T1 engage motor in the main drive unit is defective. i) Rotate the motor manually. • If the motor operation is stiff, replace the motor(JC93-00452A). ii) Measure the resistance value with DVM. • If the measured value is out of the standard area (7~10 ohm), replace the motor(JC93-00452A). b) If the motor is normal, measure the motor signal with DVM. • If the phase output voltage is changed in 0~24V(8~10V), the output value is normal. • If the phase output voltage is not changed to 0 or 24V, replace the main board(JC92-02429A).

← Xem tất cả mã lỗi Samsung CLX9251ND

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie