Mã lỗi A1-2511, A1-2512, A1-2513 — Samsung CLX9301NA

Code: A1-2511, A1-2512, A1-2513

Display: Motor Failure: #A1-2511. Turn off then on. Call for service if the problem persists Motor Failure: #A1-2512. Turn off then on. Call for service if the problem persists Motor Failure: #A1-2513. Turn off then on. Call for service if the problem persists
Description: Black OPC motor operation is abnormal.
Remedy: • A1-2511 : Black OPC motor is stopped but machine recognizes it as operational. • A1-2512 : Black OPC motor is not operated for print-job. • A1-2513 : Black OPC motor is operating but machine recognizes status as "Stopped". 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around black drum drive unit. 3) Remove the rear cover after removing 10 screws. 4) Check if the black OPC motor connector is connected correctly. 5) If the connection is OK, turn the machine on. Enter SVC mode. Select the black OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100-0044) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)). - If the control signal is abnormal, replace the main board(JC92-02429A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.

← Xem tất cả mã lỗi Samsung CLX9301NA

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie