Display: Fan Failure: #. Turn off then on. Call for service if the problem persists
Description: SMPS or Fuser fan is not operational.
Remedy: NOTE • SMPS fan error : A2-1211 / A2-1212 • Fuser fan error : A2-2310 / A2-2311 1) Turn the machine off. 2) Remove the rear cover. 3) Check if the corresponding fan connector is connected correctly. 4) If the connection is OK, Enter SVC mode and execute fan test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 100-0260 : SMPS Fan Run • 109-0040 : Fuser Fan Run 5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31-00161A • SMPS Fan : JC31-00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02429A). 6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.