Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi U1-2113, U1-2131, U1-2141 — Samsung ML2545

Code: U1-2113, U1-2131, U1-2141

Display: Fuser Unit Failure #: Turn off then on.
Description: The temperature control of fuser unit is abnormal. (U1-2113 : Open heat error / U1-2131 : Low heat error / U1-2141 Over heat error)
Remedy: 1) Turn the machine off and turn it on again. 2) Check the following : a) Check the power voltage of the fuser unit. (110V, 220V) b) Check if the Heat lamp is broken. c) Check if the AC connection of Heat lamp is disconnected or contaminated. d) Check if the thermostat is blown. e) Check if there is any jammed paper in fuser unit. f) Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?) 3) If the problem persists, replace the fuser unit. 4) If the problem persists after replacing the fuser unit, replace the main board or SMPS.

← Xem tất cả mã lỗi Samsung ML2545