Description: Rear Jogger Home Sensor, Rear Jogger Motor harness connection not well or damaged, Main Board damaged.
Remedy: 1) Check the Main Board Harness Connection. 2) Check the Finisher Rear Jogger Home Sensor’s harness connection. 3) Check the Finisher Rear Jogger Motor’s harness connection and operation. 4) Check if Rear jogger part is contaminated, broken or binding. 5) If the same problem happens after checking 1-4, Replace the Finisher main board. 6) If the same problem happens after checking 5, Replace the Finisher harnesses.