Mã lỗi U1-2320, U1-2330 — Samsung ML5015ND

Code: U1-2320, U1-2330

Display: Fuser Unit Failure #U1-2320 : Turn off then on. Fuser Unit Failure #U1-2330 : Turn off then on.
Description: Fuser Open heat error or Low heat error has occurred.
Remedy: 1) After checking the fuser installation, turn the machine off then on. 2) Open the rear cover. Lift up the right side and release the rear cover. 3) If there is no problem, remove 4 screws. 4) Lift up the both levers. Then take off the fuser unit. 5) Remove the Frame-cover-upper after removing 2 screws. And measure the thermostat continuity. Check if the thermostat is opened. 6) Measure the LAMP-HALOGEN resistance value from the center and both sides. Check if it has the continuity. 7) Check if the Draw-connector harness is correct. Check its color. 8) Check if 2 thermistor connectors are connected properly. 9) Remove the thermistor. Check if the thermistor has curled as shown below. If there is any contamination on the film, clean it. 10)Check if the thermistor connector on the main board is connected properly. 11) Check if the FDB connector is connected properly. 12)Check if the voltage in user environment is in this range (80V - 140V, 160V - 260V). 13)If there is no problems for above steps, update the firmware. 14)Replace the FDB. If the problem persists, replace the main board.