Code: U1-2340
Display: Fuser Unit Failure #U1-2340 : Turn off then on.
Description: Fuser Over heat error has occurred.
Remedy: 1) After checking the fuser installation, turn the machine off then on. 2) Open the rear cover. Lift up the right side and release the rear cover. 3) If there is no problem, remove 4 screws. 4) Lift up the both levers. Then take off the fuser unit. 5) Remove the Fuser Side-cover-R. Check the surface on Drum-fuser belt and Pressure roller. If there is any overheated mark, replace fuser unit. 6) Check if the Draw-connector harness is correct. Check its color. 7) Check if 2 thermistor connectors are connected properly. 8) Remove the thermistor. Check if the thermistor has curled as shown below. If there is any contamination on the film, clean it. 9) Check if the thermistor connector on the main board is connected properly. 10)Remove the FDB. Check the Triac short on FDB. Measure the transistor resistance for each terminal. If there is any problem, replace the FDB. 11) If the problem persists, replace the main board. If the fuser unit is damaged, replace it with new one.