Code: U1-2340
Display: Fuser Unit Failure: #U1-2340. Turn off then on
Description: The overheat error has occurred.
Remedy: 1. Check if the fuser unit is installed properly. Turn the machine off then on. 2. Remove the fuser unit after removing 4 screws. 3. Check if the fuser unit is overheated. a. Remove the GUIDE-EXIT LOWER. To remove it, fi rst, push and release the green lever to the direction of arrow. Then, lift and pull it. b. Rotate the gear to direction of arrow and check the surface of the Hear roller and Pressure roller. If there is any overheated traces, replace the fuser unit. c. Remove the COVER-UPPER. Check if the thermistor harness is connected properly and the thermistor is defective. 4. Remove the thermistor. Check if the thermistor has curled as shown below. If there is any contamination on the fi lm, clean it. Caution - Be careful not to be scratched or curled the film. 6. Measure the thermostat resistance. Check if the thermostat is opened. Although the thermostat is opened, check the following steps. And then replace the fuser unit. 7. Remove the FDB cover. Check if the FDB Triac is short. Check the resistance among 3 legs of both transistors. If it is short, replace the FDB. 8. If there is no problem for above steps, repalce the FDB, engine board step by step. If the fuser unit is defective, replace it.