Mã lỗi A1-1110 — Samsung ML6510ND

Code: A1-1110

Display: Actuator Motor Failure #A1-1110: Turn off then on.
Description: After working the main BLDC motor, the Ready signal has not occurred within 1 sec. 1. Harness is defective. Connector is not connected properly. 2. OPC coupler in the imaging unit has overloaded. 3. Main BLDC motor is defective. 4. Engine board is defective.
Remedy: First, turn the machine off then on. If the error persists, refer to the following. 1. Check if the connector is connected properly. Reconnect it. 2. OPC coupler has overloaded. After removing the imaging unit, rotate the OPC coupler. If there is any damage, the OPC coupler can’t rotate well. Replace the imaging unit. 3. The main BLDC motor is defective. - Unplug the connector from the motor. - Replace the main BLDC motor with new one. 4. If the problem persists, replace the engine board.