Mã lỗi U1-2320 — Samsung ML6512ND

Code: U1-2320

Display: Fuser Unit Failure: #U1-2320. Turn off then on
Description: The fuser unit is not installed or AC is not supplied to the Heat Lamp. Thermistor is defective.
Remedy: 1. Check if the fuser unit is installed properly. Turn the machine off then on. 2. Remove the fuser unit. Remove the COVER-UPPER. And measure the thermostat continuity. Check if the thermostat is opened. 3. Measure the LAMP-HALOGEN resistance value from the center and both sides. Check if it has the continuity. 4. Check if 2 thermistor connectors are connected properly. 5. Remove the thermistor. Check if the thermistor has curled as shown below. If there is any contamination on the fi lm, clean it. Caution - Be careful not to be scratched or curled the film. 6. Check if the thermistor connector on the engine board is connected properly. 7. Check if the FDB connector is connected properly. 8. Check if the voltage in user environment is in this range (80V - 140V, 160V - 260V). 9. Replace the FDB. If the problem persists, replace the engine board.