Display: Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists The room temperature is not suitable for this set use. Please adjust room temperature
Description: Outer temperature/humidity sensor is defective.
Remedy: 1) Enter SVC mode. Execute sensor test to check its operation. (Diagnostics > Engine Diagnostics > Engine Test Routines > Outer Temperature) 2) Measure the resistance value of the connector at both ends. If the value is not in 47.5K - 52.5K(@ 25C), replace the outer temperature/humidity sensor(JC32-00005A). 3) If the harness and sensor are normal, replace the main board(JC92.02722A).