Code: U1–2115, U1–2116
Display: Fuser unit Failure: #U1-2115. Turn off then on. Call for service if the problem persists Fuser unit Failure: #U1-2116. Turn off then on. Call for service if the problem persists
Description: The pressure control unit(Cam unit)of the fuser is abnormal.
Remedy: CAUTION The temperature gets hot around the fuser unit. To prevent burns, make sure the fuser unit area is cool before performing this procedure. 1) After checking the fuser installation, turn the machine off then on. 2) Open the rear cover. Lift up the right side and release the rear cover. 3) If there is no problem, remove 4 screws. 4) Lift up the both levers. Then take off the fuser unit. 5) Remove the fuser side cover L/R. Check if the Actuator cam, Gear cam are assembled correctly. 6) If there is no problem for above steps, assemble and reinstall fuser unit. Then turn the machine on. 7) If the same error persists, perform a Memory Clear (backup data in SWS first); if that does not work try reinstalling the firmware. 8) If the same error persists, replace the fuser unit(JC91–01177A (220V) / JC91–01176A (110V)) with new one. 9) If the same error persists, replace the main board(JC92–02722A).