Mã lỗi U2-1112, U2-1113 — Samsung SCX4728FD

Code: U2-1112, U2-1113

Display: Error #U2-1112 Turn off then on Error #U2-1113 Turn off then on
Description: LSU Motor does not work normally.
Remedy: 1) Execute the LSU motor test in EDC program. Check the LSU motor operation sound. 2) If there is no sound, remove the right cover. Check if the LSU harness on the main board is connected properly. (picture- ,) 3) If it is OK, remove the top cover. Check if the LSU harness on LSU board is connected properly. (picture- ,) 4) Check if the LSU harness is defective. (picture- ,) 5) Reconnect the LSU harness and then execute the LSU motor test in EDC program again. 6) If the problem persists, replace the LSU. 7) If the problem persists after replacing LSU, replace the main board.