Display: Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists. Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists.
Description: Regi/MP motor does not operate. / Regi/MP motor is operational but registers status as stopped.
Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit. 3) Remove the Rear-cover. 4) Check if the Regi/MP motor connector is connected correctly. 5) If the connection is OK, turn the machine on. Enter the SVC mode. Select the motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines >100-0000) a) If the motor does not operates, i) Check the signal and power with the DVM. ii) If the checked result is normal, replace the BLDC motor(JC93-00448A). iii) If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100A (220V) / JC44-00093A (110V)) - If the control signal is abnormal, replace the Main board(JC92-02452A). b) If the motor is operational, check the Pin Num 8. i) If the value is abnormal, replace the Main board(JC92-02452A). ii) If the value is normal, replace the harness.