Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi U2-1111, U2-1112, U2-1113, U2-1114 — Samsung SCX8123NA

Code: U2-1111, U2-1112, U2-1113, U2-1114

Display: LSU Failure: #. Turn off then on.
Description: LSU motor does not operate of it operates abnormally. Motor ready signal is abnormal.
Remedy: 1) Turn the machine off then on. Check for the LSU motor operation sound during warm-up. 2) Print a Demo page and check the printout is normal. 3) If the problem persists, check the following: • If the LSU motor makes a sound, a) By SVC mode, Check if the motor ready signal is occurred. (Diagnostics > Engine Diagnostics > Engine Test Routines > 110-0000) b) If not, open the side-cover and replace the LSU(JC97-04017A) • If the LSU motor does not make a sound, a) Unplug and reconnect the LSU flat cable connecting the LSU. Then check the operation sound of LSU. b) Unplug and reconnect the LSU flat cable on main board. Then check the operation sound of LSU. c) If the LSU flat cable is defective, replace FFC(JC39-01657A) d) If the LSU cable is OK, replace the LSU(JC97-04017A)