Mã lỗi U1-2316, U1-2317 — Samsung SCX8123ND

Code: U1-2316, U1-2317

Display: Fuser Unit Failure: #U1-2316. Fuser Unit Failure: #U1-2317.
Description: Temperature of the fuser changes abnormally
Remedy: • U1-2316 : Error occurs at non-contact type Thermistor • U1-2317 : Error occurs at contact type Thermistor 1) Turn the machine off. Re-install the fuser unit, then turn the machine on. (Refer to 3.2.2. Fuser unit) 2) Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?) 3) If the problem persists, Check the following: (Refer to 3.3.23. Fuser unit) a) Check if the Halogen lamp (110V : 4713-001632 / 220V : 4713-001633) is broken or disconnected. b) Check if the AC connection of the Halogen lamp is disconnected or contaminated. c) Check if the thermistat(4712-001098) is disconnected. d) Check if the contact type thermistor(1404-001567) or Non-contact type thermistor(1404-001453) is broken. 4) If the problem persists, replace the Fuser unit(110V : JC91-01049A / 220V : JC91-01050A). 5) If the problem persists, replace the Main board(JC92-02452A) or FDB board(110V : JC44-00210A, 220V : JC44-00211A), SMPS(110V : JC44-00093A, 220V : JC44-00100A)