Display: Motor Failure: #. Turn off then on. Call for service if the problem persists.
Description: Toner is not supplied normally.
Remedy: 1) Open the front cover. If the toner pipe is blocked, open it. 2) Turn the machine off then on. If the error persists, check the following steps. 3) Enter the SVC mode. Select the toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 111-0040) 4) If the motor does not operate, measure the motor power with DVM. - Measure 2points together. a) If 24V power is supplied, replace the Toner supply motor(JC31-00123B). b) If 24V power is not supplied, check the SMPS and main moard i) If 24V power is not generated, replace the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)). ii) If the control signal is abnormal, replace the Main board(JC92-02452A).