Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi A2-2810, A2-2811, A2-2910, A2-2911 — Samsung SCX8128NA

Code: A2-2810, A2-2811, A2-2910, A2-2911

Display: Fan Failure: #. Turn off then on. Call for service if the problem persists.
Description: Ozone Fan or OPC In fan fan does not operate.
Remedy: NOTE • Ozone fan error : A2-2810 / A2-2811 • OPC In fan error : A2-2910 / A2-2911 1) Turn the machine off. 2) Remove the rear cover. 3) Check if the corresponding fan connector is connected correctly. 4) If the connection is OK, enter the SVC mode and execute fan test. (Diagnostics > Engine Dignostics > Engine Test Routines > 100-0260, 109-0040) 5) If the fan does not operate, measure the fan power. (Red line) - Measure the Red line a) If 24V power is generated, replace the defective fan. b) If 24V power is not generated, check the SMPS and main board. i) Measure 24V power on the SMPS board. If the SMPS board(JC44-00100A (220V) / JC44-00093A (110V)) is defective, replace it. ii) If the SMPS board is normal, replace the Main board(JC92-02452A). 6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. b) Check fan operation as connection or disconnection. i) If the Lock signal is 0V continually, check the harness. ii) If the harness is OK, replace the Main board(JC92-02452A). iii) If the signal value is different from the table above, replace the Fan(JC93-00500A).