Code: E4-10
Description: Exhaust Fan Motor Rotation (Fuser Unit Side) Inclination Detection
Causes: 1. Exhaust Fan connector is disconnected. 2. Exhaust Fan is defective. 3. LVPS connector is disconnected. 4. LVPS is defective. 5. SPC PCB is defective. 6. Inclination Sensor detected Inclination of the machine. Check the machine is placed properly, and reset the machine by unplugging the power cord from the outlet and plug the power cord again.