Code: C1300
Description: Polygon mirror motor error
- The LOCK signal is not detected within a predetermined period of time that begins 1 sec. after the Polygon Motor has been energized.
- No new LOCK signal is detected for a 1-sec. period that begins 1.5 sec. after the first LOCK signal was detected.
- The LOCK signal is not detected for a continuous 0.5-sec. period in a state in which the Polygon Motor runs stably.
- The LOCK signal remains ON for a continuous 5-sec. period or more when the Polygon Motor remains deenergized.
- The LOCK signal is not detected within a predetermined period of time that begins 1 sec. after the Polygon Motor has been energized.
- No new LOCK signal is detected for a 1-sec. period that begins 1.5 sec. after the first LOCK signal was detected.
- The LOCK signal is not detected for a continuous 0.5-sec. period in a state in which the Polygon Motor runs stably.
- The LOCK signal remains ON for a continuous 5-sec. period or more when the Polygon Motor remains deenergized.
Remedy: 1 Check cables for connection and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-P.