Code: 9F
Description: Paper empty
Causes: Dirt on PE sensor. Harness connection failure of PE EG sensor PCB ASSY. PE actuator catching on some position. PE sensor failure. HVPS PCB unit failure. Main PCB failure
Remedy: Clean the PE sensor. Check the harness connection of the PE EG sensor PCB ASSY and reconnect it. Correct catching of the PE actuator. Check the sensor performance following the procedure described in "4.10 Sensor Operational Check (Function code 32)" in Chapter 6. If any problem occurs, replace the PE PG sensor PCB ASSY. Replace the HVPS PCB unit. Replace the main PCB ASSY.