Code: C255C
Description: ATDC Adjustment Failure
- The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
- The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run.
- The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
- The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run.
Remedy: 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.