Mã lỗi C1004 — Konica-Minolta bizhub 227

Code: C1004

Description: FNS communication error (When FS-533, FS-534, FS-534SD or JS-506 is installed) <When FS-533, FS-534 or FS-534SD is installed> • When the FS control board (FSCB) is receiving data, a communication error is detected.
Causes: <When FS-533, FS-534 or FS-534SD is installed> • FS control board (FSCB) <When JS-506 is installed> • JS control board (JSCB)
Remedy: (a) When FS-533, FS-534 or FS-534SD is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-533/FS-534/FS-534SD) (b) When JS-506 is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace JSCB.