Description: Reverse cooling fan failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Reverse cooling fan (FM5) • MFP board (MFPB)
Remedy: 1. Check the connector between FM5-relay CN88-relay CN20-MFPB CN25E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM5 operation check. • Control signal: MFPB CN25E-11 (REM), MFPB CN25E-13 (LOCK) • Location of electrical component: 18-C 4. Replace FM5. 5. Replace MFPB.