Mã lỗi C0211 — Konica-Minolta bizhub 235

Code: C0211

Description: Bypass tray up/down failure
- While the bypass lift sensor (PS2) is in the OFF state after the power is turned ON, output is finished, or a paper jam is cleared, PS2 is not turned ON within the given time after the bypass pick-up solenoid (SD1) has been turned ON. Then SD1 is turned ON again, but PS2 cannot be turned ON within the given time.
- When the bypass lift sensor (PS2) is in the ON state, PS2 is not turned OFF within the given time after the bypass pick-up solenoid (SD1) has been turned ON.
Remedy: 1 Check the connector between M1-MFPB P006 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 Check the connector between CL1-relay CN3-relay CN6- MFPB P008 for proper connection and correct as necessary. 4 CL1 operation check. 5 Check the connector between SD1-relay CN4-relay CN6- MFPB P008 for proper connection and correct as necessary. 6 M1 operation check. 7 SD1 operation check. 8 Change MFPB.