Code: C5353
Description: IU Cooling Fan Motor Failure
- The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning.
- The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped.
- The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning.
- The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped.
Remedy: 1 Check the M6 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Change PWB-A.