Mã lỗi 18 — Konica-Minolta bizhub 25e

Code: 18

Description: Fuser Error. 1: Fuser started warming up but could not reach the warm-up starting temperature within specified time 2: Fuser could not reach the warm-up completion temperature within specified time 3: Printing started but could not reach the print motor driving temperature within specified time 4: Printing started but could not reach the paper feeding temperature within specified time 6: Printing started but could not reach the printing temperature within specified time 8: The fuser temperature does not rise when the heater is turned on 9: Fuser thermistor showed an abnormally high value 10: Fuser thermistor showed an abnormally low value 11: The fuser temperature does not drop after warming-up or printing has finished and a specified time has passed
Causes:
Remedy: 1. Check the connection between the fuser and main control board. 2. Replace the fuser. 3. Replace the main control board. 4. Replace the power supply unit.