Code: C3101
Description: Fusing roller separation failure
• With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating. • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating.
• With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating. • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating.
Remedy: 1 Check the connector between M11-PRCB CN13 for proper connection and correct as necessary. 2 Check the connector between fusing unit-relay CN98, CN99, CN104-PRCB CN5 for proper connection and correct as necessary. 3 PS38 I/O check, sensor check PRCB CN5-12 (ON) 27 to 28-C. 4 M11 operation check PRCB CN13-1 to 4 25-C. 5 Replace M11. 6 Replace the fusing unit. 7 PRCB IC26 conduction check. 8 Replace PRCB.