Mã lỗi C0206 — Konica-Minolta bizhub 287

Code: C0206

Description: Tray 3 lift-up failure (When PC-113 or PC-213 is installed) The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Causes: • Tray 3 lift-up motor (M113) • Tray 3 upper limit sensor (PS116) • PC control board (PCCB) • MFP board (MFPB)
Remedy: 1. Check the connector between M113-PCCB CN6 for proper connection and correct as necessary. 2. Check the connector of M113 for proper drive coupling and correct as necessary. 3. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary. 4. PS116 I/O check, sensor check • Control signal: PCCB CN4-3 (ON) • Location of electrical component: PC-113/PC-213 7-C 5. M113 operation check • Control signal: PCCB CN6-8 to 9 • Location of electrical component: PC-113/PC-213 2-C 6. Replace M113. 7. Replace PCCB. 8. MFPB F4E conduction check 9. Replace MFPB. NOTICE • Link to the wiring diagram (N.2.2 PC-113) • Link to the wiring diagram (N.2.3 PC-213)