Mã lỗi C1196 — Konica-Minolta bizhub 287

Code: C1196

Description: Center fold roller motor malfunction (When FS-534SD is installed) The guide home sensor (PS7) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the center fold roller motor (M8) is turned ON.
Causes: • Center fold roller motor (M8) • Guide home sensor (PS7) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1. Check the connector between M8-SDDB J8 for proper connection and correct as necessary. 2. Check the connector of M8 for proper drive coupling and correct as necessary. 3. Check the connector between PS7-SDDB J9 for proper connection and correct as necessary. 4. PS7 I/O check, sensor check • Control signal: SDDB J9-6 (ON) • Location of electrical component: SD-511 4-G 5. M8 operation check • Control signal: SDDB J8-11 to 14 • Location of electrical component: SD-511 2 to 3-F to G 6. Replace M8. 7. Replace SDDB. 8. Replace FSCB.