Description: Drum unit/K new release failure. The status with the new unit is not cleared after the new drum unit is set.
Causes: • Drum unit/K • MFP board (MFPB)
Remedy: 1. Clean the connection between the drum unit and the machine if dirty. 2. Reinstall the drum unit/K. 3. Check the connector between the drum unit-relay CN13-MFPB CN17E for proper connection and correct as necessary. 4. Replace the drum unit/K. 5. Replace MFPB.