Code: 132.34
Description: PC drum measurement too close to baseline.
Remedy: Step 1: Remove the transfer roll, and then check for loose toner blocking the toner density sensor. Is it free of loose toner? Yes: Go to step 2. No: Clean the sensor.
Step 2: Check the TDS for proper operation: 1. Lower the ACM assembly. 2. Move the toner density sensor wiper from left to right. Does it move freely? Yes: Go to step 3. No: Reinstall the wiper properly. If it still cannot move freely, then replace the toner density sensor.
Step 3: Check the cable JTDS for proper connection. Is it properly connected? Yes: Go to step 4. No: Reseat the cable.
Step 4: Check the cable JTDS for damage and pinch points. Is it free of damage? Yes: Replace the controller board. No: Replace the toner density sensor.
Step 2: Check the TDS for proper operation: 1. Lower the ACM assembly. 2. Move the toner density sensor wiper from left to right. Does it move freely? Yes: Go to step 3. No: Reinstall the wiper properly. If it still cannot move freely, then replace the toner density sensor.
Step 3: Check the cable JTDS for proper connection. Is it properly connected? Yes: Go to step 4. No: Reseat the cable.
Step 4: Check the cable JTDS for damage and pinch points. Is it free of damage? Yes: Replace the controller board. No: Replace the toner density sensor.