Code: 004B
Description: Toner suction fan motor's turning at abnormal timing
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the connector between FM4-relay CN43-PRCB CN6 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check. 4 Change FM4. 5 Change PRCB