Code: 0F36
Description: Abnormally low toner density detected TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Make sure that the following counter is cleared at the developer replacing. [Service Mode] -> [Supplies] -> [Life Counter Clear] -> [Developer (K)] 2 Perform image troubleshooting procedure if image density is low. 3 Reinstall developing unit 4 Reinstall toner bottle 5 Check the contact of developing unit for proper connection and correct as necessary. 6 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 7 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 8 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 9 M3 operation check 10 M8 operation check 11 Change developing unit 12 Change TCRSB 13 Change PRCB