Code: 0F3D
Description: TCR sensor adjustment failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall developing unit 2 Reinstall toner bottle 3 Check the contact of developing unit for proper connection and correct as necessary. 4 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 5 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 6 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 7 M3 operation check 8 M8 operation check 9 Change developing unit 10 Change TCRSB 11 Change PRCB