Code: C-3801 Description: Fusing main sensor low temperature abnormality. - While in the idle or in the low power mode, the fusing heater lamp /1 (L2) turns on for more than 12 seconds in succession. Causes: Thermistor /1 (TH1) Printer control board (PRCB)