Code: C-1115
Description: SD: Conveyance motor (M8) drive abnormality.
- Within a specified period of time after M8 turns ON, the ON of a motor lock signal is detected for a prescribed period of time in succession.
- A specified period of time after M8 turns OFF, the OFF of a motor lock signal is detected for a prescribed period of time in succession.
- Within a specified period of time after M8 turns ON, the ON of a motor lock signal is detected for a prescribed period of time in succession.
- A specified period of time after M8 turns OFF, the OFF of a motor lock signal is detected for a prescribed period of time in succession.
Causes: Conveyance motor (M8) SD control board (SDCB)