Code: C4101
Description: Polygon Motor Failure
- The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection)
- No First Lock signals are detected during the 1- second period that starts 1 second after a First Lock signal. (Faulty lock signal detection)
- The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection)
- The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection)
- The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection)
- No First Lock signals are detected during the 1- second period that starts 1 second after a First Lock signal. (Faulty lock signal detection)
- The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection)
- The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection)
Remedy: 1 Check the PH connector for proper connection, and correct as necessary. 2 Change PH. 3 Change PWB-A.