Code: C0204
Description: Tray 2 feeder up/down abnormality
• The paper feed tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
• The paper feed tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the connector between M21-PRCB CN11 for proper connection and correct as necessary. 2 Check the connector of M21 for proper drive coupling and correct as necessary. 3 Check the connector between PS22-relay CN6-PRCB CN14 for proper connection and correct as necessary. 4 PS22 I/O check. 5 M21 operation check. 6 Change M21. 7 Change PRCB.