Code: C11B0
Description: Stapler movement drive malfunction
<When FS-527 is installed> • During home position search, neither the stapler home sensor/1 (PS18) nor the stapler home sensor/2 (PS19) is turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M11) is turned ON. <When FS-529 is installed> • During the home position search, the stapler home sensor (PS11) is not turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M7) is turned ON.
<When FS-527 is installed> • During home position search, neither the stapler home sensor/1 (PS18) nor the stapler home sensor/2 (PS19) is turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M11) is turned ON. <When FS-529 is installed> • During the home position search, the stapler home sensor (PS11) is not turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M7) is turned ON.
Remedy: 1 Check the connector between M1-FSCB PJ8 for proper connection and correct as necessary. 2 Check the connector between PS18-FSCB PJ17 for proper connection and correct as necessary. 3 Check the connector between PS19-FSCB PJ17 for proper connection and correct as necessary. 4 Check the connector of M11 for proper drive coupling, and correct as necessary. 5 PS18 I/O check, sensor check. 6 PS19 I/O check, sensor check. 7 M11 operation check. 8 Change M11. 9 Change FSCB.